Expanding upon the heritage of the world’s most widely installed active Hydrogen maser, the Microchip MHM-2020 has enhanced the unique Auto-Tune design of the MHM-2010 by re-engineering the electronics and software to attain even better stability.

Extreme Low Phase Noise and Frequency Stability for precise timekeeping and metrology applications.

Expanding upon the heritage of the world’s most widely installed active Hydrogen maser, the Microchip MHM-2020 has enhanced the unique Auto-Tune design of the MHM-2010 by re-engineering the electronics and software to attain even better stability.
Capable of achieving < 3 × 10 -16  daily drift rates along with improved environmental stability, the MHM-2020 has been designed for applications requiring extreme frequency stability and low phase noise.
Designed, manufactured and tested in the USA with an eye toward long service deployments, 95% of Masers built at Microchip’s dedicated Maser facility since 1999 are still in operation. Each MHM-2020 is manufactured to meet stringent quality standards and undergoes extensive performance verification testing, prior to deployment.

Auto-Tune with Drift Compensation

The MHM-2020 incorporates an automatic frequency control system to maintain the resonant cavity at a constant frequency relative to the hydrogen emission line. This technique enables the Maser to deliver long-term stability that is only attributed to the most stable cesium atomic standards.
Now, by pairing this technology with the new integrated Drift Compensation software, daily aging rates of < 3 × 10 -16  can be consistently achieved with the MHM-2020.

Outputs

The MHM-2020 provides multiple 5, 10, and 100 MHz outputs and 1PPS. Multiple configurations can be ordered to optimize for varied applications.Low Phase Noise Output Option

The MHM-2020 can be factory configured with low phase noise outputs that enable higher resolution measurements in VLBI applications.


Key Features

  • Telemetry monitoring via Touch screen and secure Ethernet
  • Dedicated keypad or USB/serial port (secure) allow flexibility in instrument control
  • Drift compensation mode enabling drift as low as <3 x 10-16 /day (typical, after 3 months)
  • Low hydrogen usage for extended maintenance-free operation and Demonstrated lifetime of greater than 20 years
  • Internal Time-of-Day clock for internal data time stamping
  • 1PPS synchronization option for precise calibration to GNSS
  • Multiple 1PPS and RF output options (5, 10 or 100 MHz)
  • Low phase noise option
  • Battery back-up
  • CE compliant